Construction and installation of fortified rooms in existing apartments and homes.

Cat. No. BMFR-001/007

The fortified room, made entirely of reinforced concrete, permanently strengthens the structure it is installed in.

During normal use, the fortified room looks exactly like one of the home’s regular rooms, it has a window, an air conditioner, telephone and more.

In an emergency, the fortified room provides effective, close at hand and immediately available protection from missiles and rockets.

In Israel, following the first Gulf War, a law was passed that required all new or extended homes and apartments to include a fortified room (as opposed to an underground shelter). This is due to the fact that early warning of a missile attack is far too short to allow for safe evacuation to a distant bomb shelter but sufficient to access a fortified room within the home. What in the past took minutes, is now possible in seconds and can be the difference between life and death!

Home Front Command has a detailed series of rules and regulations governing the construction of a fortified room. This includes the fact that the door and window of all fortified rooms must be blast and shrapnel resistant and gas proof (airtight). In addition, every fortified room must have a ventilation system and a chemical/biological filter system. It’s also possible to install air conditioners for regular and emergency use.

Mifram has a great deal of experience in the design and construction of thousands of fortified rooms that meet the strict requirements of Home Front Command. Adding a fortified room to an existing structure requires getting permits – a long and complex bureaucratic procedure that can deter many home owners. Mifram’s experts, backed up with the experience of thousands of successfully constructed and installed units, will assist you in successfully navigating the bureaucratic obstacle course.

Dimensions *
External length3.60 m.
External width3.60 m.
External area13 SqM.
Internal length3.00 m.
Internal width3.00 m.
Internal area9 SqM.
Thickness of external wall25 cm.
Thickness of internal wall20 cm.
Floor thickness20 cm.
Ceiling thickness30 cm.
  • * Minimum dimensions as required by Home Front Command.
  • Each fortified room is constructed according to the actual dimensions of the room it is to be installed in.

Hey, you came this far ?!

contact us  at +972 72-392-2515 or fill in this form and hear about our launch prices for the newst models!

 

    Looking for a local distributor?

      For additional information:

      Call us anytime at +972 72-392-2515

      or fill in this form and we will contact you soon!

        Please use this form to introduce yourself

        Mifram Barrires Catalog

          For the full catalog of barriers, please leave your details in the form below